High Precision Digital Lcr Meter 100Hz~100kHz, At826

High Precision Digital Lcr Meter 100Hz~100kHz, At826

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.[1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.

Product Introduction

Our company believes that it is precisely because we have these excellent Used Oscilloscope Agilent DSOX4022A, Used Spectrum Analyzer Rohde & Schwarz FSW50, Semiconductor Analyzers and services that customers will choose us from the beginning. We are committed to building a professional team and high-tech production technology to manufacture high-quality products. We rely on high-quality product quality and a rich product series to provide you with a full range of solutions. Since the establishment of our company, with the corporate purpose of 'maximizing customer satisfaction and maximizing social benefits', we have fully implemented the spirit of 'quality first, excellence, and advancing with the times' to continuously optimize product quality and service quality.

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.[1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value. Readings should be reasonably accurate if the capacitor or inductor device under test does not have a significant resistive component of impedance. More advanced designs measure true inductance or capacitance, as well as the equivalent series resistance of capacitors and the Q factor of inductive components.


Usually the device under test (DUT) is subjected to an AC voltage source. The meter measures the voltage across and the current through the DUT. From the ratio of these the meter can determine the magnitude of the impedance. The phase angle between the voltage and current is also measured in more advanced instruments; in combination with the impedance, the equivalent capacitance or inductance, and resistance, of the DUT can be calculated and displayed. The meter must assume either a parallel or a series model for these two elements. An ideal capacitor has no characteristics other than capacitance, but there are no physical ideal capacitors. All real capacitors have a little inductance, a little resistance, and some defects causing inefficiency. These can be seen as inductance or resistance in series with the ideal capacitor or in parallel with it. And so likewise with inductors. Even resistors can have inductance (especially if they are wire wound types) and capacitance as a consequence of the way they are constructed. The most useful assumption, and the one usually adopted, is that LR measurements have the elements in series (as is necessarily the case in an inductor's coil) and that CR measurements have the elements in parallel (as is necessarily the case between a capacitor's 'plates'). Leakage is a special case in capacitors, as the leakage is necessarily across the capacitor plates, that is, in series.


An LCR meter can also be used to measure the inductance variation with respect to the rotor position in permanent magnet machines. (However, care must be taken, as some LCR meters will be damaged by the generated EMF produced by turning the rotor of a permanent-magnet motor; in particular those intended for electronic component measurements.)


Handheld LCR meters typically have selectable test frequencies of 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz for top end meters. The display resolution and measurement range capability will typically change with the applied test frequency since the circuitry is more sensitive or less for a given component (i.e., an inductor or capacitor) as the test frequency changes.


Benchtop LCR meters sometimes have selectable test frequencies of more than 100 kHz. They often include options to superimpose a DC voltage or current on the AC measuring signal. Lower end meters might offer the possibility to externally supply these DC voltages or currents while higher end devices can supply them internally. In addition benchtop meters typically allow the usage of special fixtures (i.e., Kelvin wiring, that is to say, 4-wire connections) to measure SMD components, air-core coils or transformers.


We will uphold our business philosophy of 'professionalism, technology, integrity' and be a high-end manufacturer of High Precision Digital Lcr Meter 100Hz~100kHz, At826. We will continue to move customers with sincere service and create value for them forever! The company has gathered a group of top technical and managerial talents in the industry. Looking forward to your inquiry.

Hot Tags: precision lcr meter, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Power Supply Mainframe Agilent N6701A, Used Noise Figure Meter Agilent 8970B, Used Signal Generator Agilent E4431B, Used Electrical Safety Analyzer Chroma 19032, Used Power Analyzer Yokogawa WT1800, Used Power Source Agilent 6812B

Send Inquiry

Home

skype

E-mail

Inquiry