Used Oscilloscope Agilent DSOX3012A

Used Oscilloscope Agilent DSOX3012A

●One million waveforms per second update rate
●MegaZoom IV smart memory technology
●Large 8.5-inch WVGA display
●Optional segmented memory

Product Introduction

The Keysight  DSOX3012A ( Agilent) is a two-channel model in the InfiniiVision 3000 X-Series. Engineered with breakthrough technology this upgradable oscilloscope provides superior performance and functionality. Its unique 5-instruments-in-one design delivers more scope for the same budget.


Features and Specifications of:

Features of:

●One million waveforms per second update rate

●MegaZoom IV smart memory technology

●Large 8.5-inch WVGA display

●Optional segmented memory

●Industry's first 5-instruments-in-1:

oOscilloscope  

oDigital channels

oBuilt-in 20 MHz function/arbitrary waveform generator with modulation

oIntegrated digital voltmeter

oProtocol analyzer

●Investment protection with Industry's only fully-upgradable oscilloscope, including bandwidth up to 1 GHz

●Industry's leading applications solution

Specifications of the Agilent DSOX3012A include:

●Bandwidth (-3 dB):  100 MHz

●Calculated rise time (10 - 90%):  ≤ 3.5 ns

●Input channels:  2 analog channels

●Maximum sample rate:

o4 GSa/s half channel

o2 GSa/s all channel

●Maximum memory depth:

oStandard 2 Mpts

oOptional 4 Mpts

oOptional segment memory

●Display size and type:  8.5 WVGA display

●Waveform update rate:  > 1 million waveforms per second

●Number of active probes supported:  In general, one for 2-channel models

●Vertical system analog channels:

oHardware bandwidth limits:  Approximately 20 MHz (selectable)

oInput coupling:  AC, DC

oInput impedance:  Selectable:  

■1 MΩ ± 1% (14 pF)

■50 Ω ± 1.5%

oInput sensitivity range:  1mV/div to 5 V/div (1 MΩ and 50 Ω)

oVertical resolution:  8 bits (measurement resolution is 12 bits with averaging)

oMaximum input voltage:

■300 Vrms, 400 Vpk

■Transient overvoltage 1.6 kVpk

■With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms

■Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk

oDC vertical accuracy:  ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]

oDC vertical gain accuracy: ± 2.0% full scale

oDC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting

oChannel-to-channel isolation:  > 100:1 from DC to maximum specified bandwidth of each model (measured with same V/div and coupling on channels)

oOffset range:

■± 2 V (1 mV/div to 200 mV/div)

■± 50 V (> 200 mV/div to 5 mV/div)

●Vertical system digital channels:

oDigital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)

oThresholds: Threshold per pod

oThreshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)

oUser-defined threshold range:  ± 8.0 V in 10 mV steps

oMaximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk

oThreshold accuracy:  ± (100 mV + 3% of threshold setting)

oMaximum input dynamic range:  ± 10 V about threshold

oMinimum voltage swing:  5 mVpp

oInput impedance:  100 kΩ ± 2% at probe tip

oInput capacitance:  ~8 pF

oVertical resolution: 1 bit

●Horizontal system analog channels:  

oTime base range:  5 ns/div to 50 s/div

oTime base accuracy:  25 ppm ± 5 ppm per year (aging)

oTime base delay time range:

■Pre-trigger:  Greater of 1 screen width or 250 μs  

■Post-trigger:  1 s to 500 s

oChannel-to-channel deskew range:  ± 100 ns

oΔ Time accuracy (using cursors):  ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps

oModes:  Main, zoom, roll, XY

oXY:

■On channels 1 and 2 only, Z Blanking on ext trigger input, 1.4 V threshold  

■Bandwidth:  Maximum bandwidth

■Phase error at 1 MHz: < 0.5 degree

●Horizontal system digital channels:  

oMinimum detectable pulse width:  5 ns

oChannel-to-channel skew:

■2 ns (typical)

■3 ns (maximum)

●Aquisition system:

oMaximum analog channels sample rate:  

■4 GSa/s half channel interleaved

■2 GSa/s all channel

oMaximum analog channels record length:

■2 Mpts half channel interleaved, 1 Mpts all channel (standard)

■4 Mpts half channel interleaved, 2 Mpts all channel (optional with DSOX3MEMUP (-040))

oMaximum duration of time captured at highest sampling rate (all analog channels):  500 us with 4M memory upgrade

oMaximum digital channels sample rate:  1 GSa/s

oMaximum digital channels record length:  

■1 Mpts (standard with digital channels only)

■2 Mpts (optional with DSOX3MEMUP - with digital channels only)

oModes:

■Normal:  Default mode

■Peak detect:  Capture glitches as narrow as 250 ps at all time base settings

■Averaging:  Selectable from 2, 4, 8, 16, 64, ... to 65,536

■High resolution:

■Real time boxcar averaging reduces random noise and effectively increases vertical resolution

■12 bits of resolution when ≥ 10 μs/div at 4 GSa/s

■or ≥ 20-μs/div at 2 GSa/s

■Segmented:

■Segmented memory optimizes available memory for data streams that have long dead times between activity

■Maximum segments = 1000

■Re-arm time = 1 μs (minimum time between trigger events)

●Trigger system:

oTrigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)

oTrigger modes:

■Normal (triggered): requires trigger event for scope to trigger

■Auto : triggers automatically in absence of trigger event

■Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode

■Force:  front panel button that forces a trigger

oTrigger coupling:  

■DC: DC coupled trigger

■AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal);

■High frequency reject:  cutoff frequency ~ 50 kHz

■Low frequency reject:  cutoff frequncy ~ 50 kHz 

■Noise reject:


■Selectable OFF or ON

■Decreases sensitivity 2x

oTrigger holdoff range: 40 ns to 10.00 s  

oTrigger sensitivity:

■Internal: < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div

■External:

■200 mVpp from DC to 100 MHz

■350 mVpp 100 MHz to 200 MHz

oTrigger level range:

■Any channel:  ± 6 div from center screen

■External:  ± 8 V



Hot Tags: used oscilloscope agilent dsox3012a, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Oscilloscope Agilent DSOX3032A, Used Oscilloscope Tektronix TDS5104B, Used Oscilloscope Agilent DSOX3034A, Used Oscilloscope Mainframe Agilent 86100C, Used Digital Serial Analyzer Tektronix DSA72004B, Used Serial Analyzer Tektronix MSO71254C