The Keysight MSOX4052A is a two-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The MSOX4052A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.
Features and Specifications of the Keysight MSOX4052A (Agilent) Oscilloscope include:
Features of the Agilent MSOX4052A include:
One million waveforms per second update rate
MegaZoom IV smart memory technology
Standard segmented memory
Large 12.1-inch capacitive touch display
Interface designed for touch
Innovative InfiniiScan Zone touch triggering
5 instruments in 1, with full upgradability, including bandwidth:
Oscilloscope
Logic analyzer (MSO)
Serial protocol analyzer, including USB (optional)
WaveGen 20 MHz dual channel arbitrary/function generator (optional)
Digital voltmeter (DVM) option:
with 3-digit voltage
with 5-digit frequency counter measurements
Specifications of the Keysight MSOX4052A include:
Bandwidth (-3 dB): 500 MHz
All-channel real-time bandwidth: 500 MHz
Calculated rise time (10 - 90%): ≤ 700 ps
Input channels:
2 analog
16 digital
Maximum sample rate:
5 GSa/s half channel
2.5 GSa/s all channel
Maximum memory depth: Standard 4 Mpts, standard segmented memory
Display size and type: 12.1-inch high-definition capacitive touch display
Waveform update rate: > 1 million waveforms per second
System bandwidth with N2894A standard passive probe: 500 MHz
Vertical system analog channels:
Hardware bandwidth limits: Approximately 20 MHz (selectable)
Input coupling: AC, DC
Input impedance: Selectable:
1 MΩ ± 1% (16 pF)
50 Ω ± 1.5%
Input sensitivity range: 1mV/div to 5 V/div (1 MΩ and 50 Ω)
Vertical resolution: 8 bits (measurement resolution is 12 bits with averaging)
Maximum input voltage:
300 Vrms, 400 Vpk
Transient overvoltage 1.6 kVpk
With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
DC vertical gain accuracy: ± 2.0% full scale
DC vertical offset accuracy: ± 0.1 div ± 2 mV ± 1% of offset setting
Channel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model
Offset range:
± 5 V (< 10 mV/div)
± 20 V (10 to 200 mV/div)
± 75 V (> 200 mV/div)
Vertical system digital channels:
Digital input channels: 16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
Thresholds: Threshold per pod
Threshold selections: TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
User-defined threshold range: ± 8.0 V in 10 mV steps
Maximum input voltage: ± 40 V peak CAT l; transient overvoltage 800 Vpk
Threshold accuracy: ± (100 mV + 3% of threshold setting)
Maximum input dynamic range: ± 10 V about threshold
Minimum voltage swing: 500 mVpp
Input impedance: 100 kΩ ± 2% at probe tip
Input capacitance: ~8 pF
Vertical resolution: 1 bit
Horizontal system analog channels:
Time base range: 2 ns/div to 50 s/div
Time base accuracy: ± 10 ppm
Time base delay time range:
Pre-trigger: Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
Post-trigger: 1 s to 500 s
Channel-to-channel deskew range: ± 100 ns
Δ Time accuracy (using cursors): ± 0.001% of reading ± 0.16% screen width ± 30pS
Modes: Main, zoom, roll, XY
XY:
On channels 1 and 2 only
Z Blanking on ext trigger input, 1.4 V threshold
Bandwidth: Maximum bandwidth
Phase error at 1 MHz: < 0.5 degree
Time base: 200 ns/div to 50 ms/div
Horizontal system digital channels:
Minimum detectable pulse width: 2 ns
Channel-to-channel skew:
2 ns (typical)
3 ns (maximum)
Aquisition system:
Maximum analog channels sample rate:
5 GSa/s half channel interleaved
2.5 GSa/s all channel
Maximum analog channels record length:
4 Mpts half channel interleaved
2 Mpts all channel
Maximum digital channels sample rate: 1.25 GSa/s
Maximum digital channels record length: 2 Mpts (with digital channels only)
Modes:
Normal: Default mode
Peak detect: Capture glitches as narrow as 200 ps at all time base settings
Averaging: Selectable from 2, 4, 8, 16, 64, ... to 65,536
High resolution:
Real time boxcar averaging reduces random noise and effectively increases vertical resolution
12 bits: ≥ 50 μs/div
11 bits: ≥ 20 μs/div
10 bits: ≥ 10 μs/div
9 bits: ≥ 5 μs/div
Segmented:
Segmented memory optimizes available memory for data streams that have long dead times between activity
Maximum segments = 1000
Re-arm time = 1 μs (minimum time between trigger events)
Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)
Roll:
Displays the waveform moving across the screen from right to left
Available at the time base 50 ms/div or slower
Trigger system:
Trigger sources: Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
Trigger modes:
Normal: Requires trigger event for scope to trigger
Auto : Triggers automatically in absence of trigger event
Single:
Front panel button that triggers only once on a trigger event
Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode
Force: Front panel button that forces a trigger
Trigger coupling:
DC: DC coupled trigger
AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)
High frequency reject: Cutoff frequency ~ 50 kHz
Low frequency reject: Cutoff frequency ~ 50 kHz
Noise reject:
Adds hysteresis to the trigger circuitry
Selectable OFF or ON
Decreases sensitivity 2x
Trigger holdoff range: 40 ns to 10.00 s
Trigger sensitivity:
Internal:
< 10 mV/div: greater of 1 div or 5 mV
≥ 10 mV/div: 0.6 div
External:
± 1.6 V:
40 mVpp DC to 100 MHz
70 mVpp 100 MHz to 200 MHz
± 8 V:
200 mVpp DC to 100 MHz
350 mVpp 100 MHz to 200 MHz
Trigger level range:
Any channel: ± 6 div from center screen
External:
± 8 V range = ± 8 V
± 1.6 V range = ± 1.6 V
Connectivity:
USB 2.0 hi-speed host port:
x3 ports, 2 front and one rear panel
Supports memory devices, printers, keybords and mice
USB 2.0 hi-speed device port:
One port on rear panel
USB Test & Measurement Class (USBTMC) compatible
LAN port:
10/100Base-T port on rear panel
LXI IPv6 extended function
Web remote control: VNC Web interface (via major Web browsers)
Video out port:
SVGA out on rear panel
Connect oscilloscope display to an external monitor or projector
GPIB port: N4865A GPIB-to-LAN adapter (optional)
10 MHz out/in:
BNC connector on the rear panel
Suported modes: Off, 10 MHz out, or reference signal mode (10 MHz in)
Trigger out:
BNC connecter on the rear panel
Supported modes: triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse
Hot Tags: agilent msox4052a, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Oscilloscope Tektronix TDS7404B, Used Oscilloscope Agilent DSO6104A, Used Oscilloscope Tektronix DPO3014, Used Serial Analyzer Tektronix MSO71254C, Used Oscilloscope Agilent DSO7014A, Used Oscilloscope Agilent DSOX3054A