Zc2820 Precision Lcr Testing Meter

Zc2820 Precision Lcr Testing Meter

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.[1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.

Product Introduction

We will provide you with customized solutions through professional services, in order to save money and expand revenue, we will provide you with the most appropriate design and Used Signal Generator Agilent N5183B, Used FieldFox Network Analyzer Agilent N9925A, Used Curve Tracer Tektronix 370A with the lowest cost and the best service. The product performance has reached the international advanced level of similar products. After years of careful management, we have established a good reputation for high quality, low price and good service. At the same time, we should make good use of the vigorous development of China's economy to expand and deepen international exchanges and cooperation.

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.[1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value. Readings should be reasonably accurate if the capacitor or inductor device under test does not have a significant resistive component of impedance. More advanced designs measure true inductance or capacitance, as well as the equivalent series resistance of capacitors and the Q factor of inductive components.


Usually the device under test (DUT) is subjected to an AC voltage source. The meter measures the voltage across and the current through the DUT. From the ratio of these the meter can determine the magnitude of the impedance. The phase angle between the voltage and current is also measured in more advanced instruments; in combination with the impedance, the equivalent capacitance or inductance, and resistance, of the DUT can be calculated and displayed. The meter must assume either a parallel or a series model for these two elements. An ideal capacitor has no characteristics other than capacitance, but there are no physical ideal capacitors. All real capacitors have a little inductance, a little resistance, and some defects causing inefficiency. These can be seen as inductance or resistance in series with the ideal capacitor or in parallel with it. And so likewise with inductors. Even resistors can have inductance (especially if they are wire wound types) and capacitance as a consequence of the way they are constructed. The most useful assumption, and the one usually adopted, is that LR measurements have the elements in series (as is necessarily the case in an inductor's coil) and that CR measurements have the elements in parallel (as is necessarily the case between a capacitor's 'plates'). Leakage is a special case in capacitors, as the leakage is necessarily across the capacitor plates, that is, in series.


An LCR meter can also be used to measure the inductance variation with respect to the rotor position in permanent magnet machines. (However, care must be taken, as some LCR meters will be damaged by the generated EMF produced by turning the rotor of a permanent-magnet motor; in particular those intended for electronic component measurements.)


Handheld LCR meters typically have selectable test frequencies of 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz for top end meters. The display resolution and measurement range capability will typically change with the applied test frequency since the circuitry is more sensitive or less for a given component (i.e., an inductor or capacitor) as the test frequency changes.


Benchtop LCR meters sometimes have selectable test frequencies of more than 100 kHz. They often include options to superimpose a DC voltage or current on the AC measuring signal. Lower end meters might offer the possibility to externally supply these DC voltages or currents while higher end devices can supply them internally. In addition benchtop meters typically allow the usage of special fixtures (i.e., Kelvin wiring, that is to say, 4-wire connections) to measure SMD components, air-core coils or transformers.


We will state with absolute certainty that for Zc2820 Precision Lcr Testing Meter. In order to further strengthen the construction of corporate culture, combined with the actual development of the company, we have formulated a series of plans and measures. In the hopeful future, our company will always grasp the pulse of the market with the spirit and vitality of pioneering and enterprising, sincerely cooperate with all walks of life and create a brilliant future with the principle of integrity and common benefit.

Hot Tags: precision lcr meter, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Signal Analyzer Rohde Schwarz FSQ26, Used Network Analyzer Agilent N5245A, Used SourceMeter Keithley 2461, Used Arbitrary Waveform Generator SR DS345, Used Network Analyzer Agilent 8753E, Used Radio Test Set Aeroflex 3920B

Send Inquiry