The Tektronix DPO7104C has built-in analysis tools that provide 53 automated measurements including measurement statistics, histograms, advanced waveform math, user-definable filters, and custom MATLAB and .NET math plug-ins.

Product Introduction

Our company closely follows the requirements of the times for the enterprise, creates and manufactures the Used Signal Generator Agilent N5183A, Used Module Agilent 86109B, Used Battery Insulation Tester Chroma 11210 needed by the consumers, so as to meet the market demand. Everything in our business is centered on 'creating value for target customers'. In the short term, our goal is to achieve a major leap from product manufacturing to brand management, from capital integration to capital operation.

The Tektronix DPO7104C Digital Phosphor Oscilloscope provides feature-packed tools to simplify operation and quickly diagnose and debug complex, mixed signal designs. The DPO7104C Oscilloscope's high bandwidth helps achieve more accurate characterizations of designs by optimizing the oscillocope's performance individually by channel. Its fast real-time sample rate improves design validation by accurately sampling signal to ensure all frequency content is being acquired and displayed. Wave Inspector® controls provide easy navigation and automated search of waveform data. The Tektronix DPO7104C has built-in analysis tools that provide 53 automated measurements including measurement statistics, histograms, advanced waveform math, user-definable filters, and custom MATLAB and .NET math plug-ins.


Features and Specifications of:

●Features:

oPerformance:

■Up to 500 Megapoint Record Length with MultiView Zoom™

■FastAcq™

■provides >250,000 wfms/s maximum waveform capture rate

■helps to quickly discover glitches, infrequent events, and elusive anomalies

■FastFrame™ segmented memory acquisition mode with >310,000 Waveforms/s capture rate

■User-selectable bandwidth limit filters for better low-frequency measurement accuracy

oEase-of-use Features:

■Pinpoint® Triggering provides the most flexible and highest performance triggering with over 1400 available trigger combinations to address virtually any triggering situation

■Optional Visual Trigger precisely quailfies triggers, finds unique events in complex wavefroms, and enables graphical trigger definition

■Advanced search and mark to find specific events in the entire waveform

■MyScope® custom control windows and right mouse click menus for exceptional efficiency

■TekVPI™ Probe Interface supports active, differential, and current probes for automatic scaling and units

■Up to 40 GS/s and 400 Meg record length with options

■12.1" (307 mm) bright XGA color display with touch screen

oConnectivity:

■USB Host Ports on the dront and side panels for quick and easy data storage, printing, and connecting USB peripherals

■Integrated 10/100/1000BASE-T Ethernet Port for network connection and video out port to export the oscilloscope display to a monitor or projector

■Microsoft® Windows 7 64-bit operating system for easy connectivity and Integration into your environment

■LXI Class C compliant

oOptional Serial Triggering and Analysis:

■Automated serial triggering, decode, and search options for I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and USB 2.0

■Automated serial analysis options for MIPI® D-PHY DSI-1 and CSI-2, 8b/10b, and PCI Express

■Clock recovery from serial data streams

■64-bit NRZ serial pattern trigger for isolation of pattern-dependent effects up to 1.25 Gb/s

oOptional Technology Specific Analysis:

■Over 15 software solutions packages provide built-in domain expertise for MIPI® D-PHY, Ethernet, MOST, and USB 2.0 compliance testing, jitter, timing, eye diagrams, power, DDR memory bus analysis, and wideband RF

■Limit and mask testing provide quick insight into signal characteristics


●Specifications:

oVertical System Analog Channels:

■Input channels:  4

■Bandwidth:  1 GHz

■Rise time 10% to 90% (typical):  300 ps

■Rise Time 20% to 80 % (typical):  200 ps

■DC Gain Accuracy:  ±1% with offset/position set to 0

■Effective number of bits:  6.7 bits

■Input Coupling:  AC, DC, GND

■Input Inpedance:  1 MΩ ±1% with 13 pF ±2 pF, 50 Ω ±1%

■Input Sensitivity:

■MΩ: 1 mV/div to 10 V/div

■50 Ω: 1 mV/div to 1 V/div

■Vertical Resolution:  8 bit (>11 bit with Hi Res)

■Max Input Voltage, 1 MΩ:  ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz

■Max Input Voltage, 50 Ω:  5 VRMS, with peaks ≤ ±24 V

■Position Range:  ±5 divisions

■Delay between any 2 channels (typical):  ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)

■Offset Range:

■1 mV/div to 50 mV/div:  ±1 V

■50.5 mV/div to 99.5 mV/div:  ±(1.5 V – 10 divisions)

■100 mV/div to 500 mV/div:  ±10 V

■505 mV/div to 995 mV/div:  ±(15 V – 10 divisions)

■1 V/div to 5 V/div:  ±100 V

■5.05 V/div to 10 V/div:  ±(150 V – 10 divisions)

■Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical):

■≥100:1 at ≤100 MHz

≥30:1 between 100 MHz and 2.5 GHz

≥20:1 between 2.5 GHz and 3.5 GHz

oHorizontal System Analog Channels:

■Maximum sample rate (1 ch):  20 GS/s

■Maximum sample rate (2 ch):  10 GS/s

■Maximum sampe rate (3-4 ch):  5 GS/s

■Maximum equivalent time sampling rate:  4 TS/s

■Maximum record length with standard configuration:  50M (1 ch), 25M (2 ch), 12.5M (3-4 ch)

■Maximum duration at highest real-time sample rate (1 ch): 

■1-2 ms with standard record length

■up to 10 ms with optional record length

■Time base range:  1.25 ps/div to 1000 s/div

■Time resolution (in ET / IT mode):  500 fs

■Time base delay time range:  -10 divisions to 1000 s

■Channel-to-channel deskew range:  ±75 ns

■Delta time measurement accuracy:  ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS

■Trigger jitter (RMS): 

■1.5 psRMS with enhanced triggering OFF

■Jitter noise floor: 

■Time base accuracy:  ±2.5 ppm + aging


With our loaded practical experience and thoughtful solutions, we now have been identified for a trusted provider for numerous intercontinental consumers for Chinese wholesale Cat Diesel Excavators Injecor 317-2300 (320-0690) Injector for C6.6 D18m01y13p4752 C6.4 .... Our entrepreneurial spirit is the collective spirit that all staff members practice their values, which is cultivated through long-term practice and reflected in their behavior. We hope to promote the transformation of quality and efficiency and improve our position in the global industrial value chain.

Hot Tags: used oscilloscope tektronix dpo7104c, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Network Analyzer Agilent 8720B, Used Real Time Spectrum Analyzer Rohde Schwarz FSVR30, Used Universal Counter Agilent 53132A, Used Audio Analyzer Rohde Schwarz UPV, Used Universal Counter Agilent 53131A, Used Network Analyzer Agilent N5234A

Send Inquiry