10Hz~20kHz Precision Digital Lcr Meter with 0.05 Accuracy At3810A

10Hz~20kHz Precision Digital Lcr Meter with 0.05 Accuracy At3810A

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.[1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.

Product Introduction

At a new starting point, our company will establish a new management concept, pursue continuous innovation and development of products, provide you with higher quality Used Capacitance Meter Agilent E4981A, Used Test Set Agilent 35677A, Used Network Analyzer Anritsu 37247D and quality services and create a new era of value-added brand. Our design always starts from the details to meet the requirements of every detail in use. In the design, we try to think more, understand more and do more. While expanding the domestic market, we aim at the international market. Our company pays attention to the construction of enterprise culture, enriches employees' spare time cultural activities, actively cultivates young reserve talents and continuously pours vitality into the development of the enterprise.

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.[1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value. Readings should be reasonably accurate if the capacitor or inductor device under test does not have a significant resistive component of impedance. More advanced designs measure true inductance or capacitance, as well as the equivalent series resistance of capacitors and the Q factor of inductive components.


Usually the device under test (DUT) is subjected to an AC voltage source. The meter measures the voltage across and the current through the DUT. From the ratio of these the meter can determine the magnitude of the impedance. The phase angle between the voltage and current is also measured in more advanced instruments; in combination with the impedance, the equivalent capacitance or inductance, and resistance, of the DUT can be calculated and displayed. The meter must assume either a parallel or a series model for these two elements. An ideal capacitor has no characteristics other than capacitance, but there are no physical ideal capacitors. All real capacitors have a little inductance, a little resistance, and some defects causing inefficiency. These can be seen as inductance or resistance in series with the ideal capacitor or in parallel with it. And so likewise with inductors. Even resistors can have inductance (especially if they are wire wound types) and capacitance as a consequence of the way they are constructed. The most useful assumption, and the one usually adopted, is that LR measurements have the elements in series (as is necessarily the case in an inductor's coil) and that CR measurements have the elements in parallel (as is necessarily the case between a capacitor's 'plates'). Leakage is a special case in capacitors, as the leakage is necessarily across the capacitor plates, that is, in series.


An LCR meter can also be used to measure the inductance variation with respect to the rotor position in permanent magnet machines. (However, care must be taken, as some LCR meters will be damaged by the generated EMF produced by turning the rotor of a permanent-magnet motor; in particular those intended for electronic component measurements.)


Handheld LCR meters typically have selectable test frequencies of 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz for top end meters. The display resolution and measurement range capability will typically change with the applied test frequency since the circuitry is more sensitive or less for a given component (i.e., an inductor or capacitor) as the test frequency changes.


Benchtop LCR meters sometimes have selectable test frequencies of more than 100 kHz. They often include options to superimpose a DC voltage or current on the AC measuring signal. Lower end meters might offer the possibility to externally supply these DC voltages or currents while higher end devices can supply them internally. In addition benchtop meters typically allow the usage of special fixtures (i.e., Kelvin wiring, that is to say, 4-wire connections) to measure SMD components, air-core coils or transformers.


To fulfill the customers' over-expected fulfillment, we have now our solid staff to deliver our greatest general assistance which includes internet marketing, product sales, creating, manufacturing, excellent controlling, packing, warehousing and logistics for 10Hz~20kHz Precision Digital Lcr Meter with 0.05 Accuracy At3810A. Our company actively develop trade relations with countries around the world and have established a global marketing network. Abiding by the principle of 'Credit first and customer supremacy', we sincerely welcome clients from home and abroad to cooperate with us and advance together to create a brilliant future.

Hot Tags: precision lcr meter, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Spectrum Analyzer Rohde Schwarz FSP40, Measurement Receiver, Used Network Analyzer Agilent 4396A, Used Semiconductor Parameter Analyzer Agilent 4156B, Used Noise Figure Meter Agilent N8974A, Used DC Power Module Agilent N6765A

Send Inquiry

Home

skype

E-mail

Inquiry