The Keysight DSOX4022A (Agilent) is a two-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The DSOX4022A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.
Features and Specifications of:
Features of:
●One million waveforms per second update rate
●MegaZoom IV smart memory technology
●Standard segmented memory
●Large 12.1-inch capacitive touch display
●Interface designed for touch
●Innovative InfiniiScan Zone touch triggering
●5 instruments in 1, with full upgradability, including bandwidth:
oOscilloscope
oLogic analyzer (MSO)
oSerial protocol analyzer, including USB (optional)
oWaveGen 20 MHz dual channel arbitrary/function generator (optional)
oDigital voltmeter (DVM) option:
■with 3-digit voltage
■with 5-digit frequency counter measurements
Specifications of the Keysight DSOX4022A (Agilent) include:
●Bandwidth (-3 dB): 200 MHz
●All-channel real-time bandwidth: 200 MHz
●Calculated rise time (10 - 90%): ≤ 1.75 ns
●Input channels: 2 analog
●Maximum sample rate:
o5 GSa/s half channel
o2.5 GSa/s all channel
●Maximum memory depth: Standard 4 Mpts, standard segmented memory
●Display size and type: 12.1-inch high-definition capacitive touch display
●Waveform update rate: > 1 million waveforms per second
●System bandwidth with N2894A standard passive probe: 200 MHz
●Vertical system analog channels:
oHardware bandwidth limits: Approximately 20 MHz (selectable)
oInput coupling: AC, DC
oInput impedance: Selectable:
■1 MΩ ± 1% (16 pF)
■50 Ω ± 1.5%
oInput sensitivity range: 1mV/div to 5 V/div (1 MΩ and 50 Ω)
oVertical resolution: 8 bits (measurement resolution is 12 bits with averaging)
oMaximum input voltage:
■300 Vrms, 400 Vpk
■Transient overvoltage 1.6 kVpk
■With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
■Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
oDC vertical gain accuracy: ± 2.0% full scale
oDC vertical offset accuracy: ± 0.1 div ± 2 mV ± 1% of offset setting
oChannel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model
oOffset range:
■± 5 V (< 10 mV/div)
■± 20 V (10 to 200 mV/div)
■± 75 V (> 200 mV/div)
●Vertical system digital channels:
oDigital input channels: 16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
oThresholds: Threshold per pod
oThreshold selections: TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
oUser-defined threshold range: ± 8.0 V in 10 mV steps
oMaximum input voltage: ± 40 V peak CAT l; transient overvoltage 800 Vpk
oThreshold accuracy: ± (100 mV + 3% of threshold setting)
oMaximum input dynamic range: ± 10 V about threshold
oMinimum voltage swing: 500 mVpp
oInput impedance: 100 kΩ ± 2% at probe tip
oInput capacitance: ~8 pF
oVertical resolution: 1 bit
●Horizontal system analog channels:
oTime base range: 2 ns/div to 50 s/div
oTime base accuracy: ± 10 ppm
oTime base delay time range:
■Pre-trigger: Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
■Post-trigger: 1 s to 500 s
oChannel-to-channel deskew range: ± 100 ns
oΔ Time accuracy (using cursors): ± 0.001% of reading ± 0.16% screen width ± 30pS
oModes: Main, zoom, roll, XY
oXY:
■On channels 1 and 2 only
■Z Blanking on ext trigger input, 1.4 V threshold
■Bandwidth: Maximum bandwidth
■Phase error at 1 MHz: < 0.5 degree
■Time base: 200 ns/div to 50 ms/div
●Horizontal system digital channels:
oMinimum detectable pulse width: 2 ns
oChannel-to-channel skew:
■2 ns (typical)
■3 ns (maximum)
●Aquisition system:
oMaximum analog channels sample rate:
■5 GSa/s half channel interleaved
■2.5 GSa/s all channel
oMaximum analog channels record length:
■4 Mpts half channel interleaved
■2 Mpts all channel
oModes:
■Normal: Default mode
■Peak detect: Capture glitches as narrow as 200 ps at all time base settings
■Averaging: Selectable from 2, 4, 8, 16, 64, ... to 65,536
■High resolution:
■Real time boxcar averaging reduces random noise and effectively increases vertical resolution
■12 bits: ≥ 50 μs/div
■11 bits: ≥ 20 μs/div
■10 bits: ≥ 10 μs/div
■9 bits: ≥ 5 μs/div
■Segmented:
■Segmented memory optimizes available memory for data streams that have long dead times between activity
■Maximum segments = 1000
■Re-arm time = 1 μs (minimum time between trigger events)
■Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)
■Roll:
■Displays the waveform moving across the screen from right to left
■Available at the time base 50 ms/div or slower
●Trigger system:
oTrigger sources: Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
oTrigger modes:
■Normal: Requires trigger event for scope to trigger
■Auto : Triggers automatically in absence of trigger event
■Single:
■Front panel button that triggers only once on a trigger event
■Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode
■Force: Front panel button that forces a trigger
oTrigger coupling:
■DC: DC coupled trigger
■AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)
■High frequency reject: Cutoff frequency ~ 50 kHz
■Low frequency reject: Cutoff frequency ~ 50 kHz
■Noise reject:
■Adds hysteresis to the trigger circuitry
■Selectable OFF or ON
■Decreases sensitivity 2x
oTrigger holdoff range: 40 ns to 10.00 s
oTrigger sensitivity:
■Internal:
■< 10 mV/div: greater of 1 div or 5 mV
■≥ 10 mV/div: 0.6 div
■External:
■± 1.6 V:
■40 mVpp DC to 100 MHz
■70 mVpp 100 MHz to 200 MHz
■± 8 V:
■200 mVpp DC to 100 MHz
■350 mVpp 100 MHz to 200 MHz
oTrigger level range:
■Any channel: ± 6 div from center screen
■External:
■± 8 V range = ± 8 V
■± 1.6 V range = ± 1.6 V
●Connectivity:
oUSB 2.0 hi-speed host port:
■x3 ports, 2 front and one rear panel
■Supports memory devices, printers, keybords and mice
oUSB 2.0 hi-speed device port:
■One port on rear panel
■USB Test & Measurement Class (USBTMC) compatible
oLAN port:
■10/100Base-T port on rear panel
■LXI IPv6 extended function
oWeb remote control: VNC Web interface (via major Web browsers)
oVideo out port:
■SVGA out on rear panel
■Connect oscilloscope display to an external monitor or projector
oGPIB port: N4865A GPIB-to-LAN adapter (optional)
o10 MHz out/in:
■BNC connector on the rear panel
■Suported modes: Off, 10 MHz out, or reference signal mode (10 MHz in)
oTrigger out:
■BNC connecter on the rear panel
■Supported modes: triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse
Hot Tags: used oscilloscope agilent dsox4022a, China, manufacturers, Suppliers, Factory, buy, low price, in stock, Used Oscilloscope Tektronix DPO4054, Used Oscilloscope Agilent MSOX3104T, Used Oscilloscope Tektronix DPO5054, Used Digital Serial Analyzer Tektronix DSA72004B, Used Oscilloscope Agilent DSOX3014A, Used Oscilloscope Tektronix DPO5204